Page 8 - FoodFocusThailand No.209 AUGUST 2023
P. 8

8-9.pdf   1   19/7/2566 BE   15:51












                                                                                                                                                                                                                       Level measurement
                                                                                                                                                                                                                       with radar

                                      LEVEL                                                                                                                                                                            The right solution for:
                                                                        PRESSURE                                                                                                                                          Small vessels – with no
                                                                                                          POINT                                                                                                            blocking distance (dead band)

                                                                                                          LEVEL                                                 LEVEL                                                      Vessels with internal fittings
                                                                                                                                                                                                                          and agitators, thanks to
                                                                                                                                                                                                                          non-contact measurement

                                                                                                                                                                                                                           Reliable measurement
                                                                                                                                                                                                                          and control – independent
                                                                                                                                                                                                                          of process conditions

                                                                                                                                                                                                                           Applications with condensation,
                                                                                                                                                                                                                          buildup or turbulent surfaces




   C
              Profit from many years of VEGA experience in                                                                                    The radar level sensor VEGAPULS 42
   M
              measurement technology
   Y                                                                                                                                         optimized for use in factory automation
   CM
   MY
              High-quality sensor technology for level,        With over 60 years of user partnerships in the field                                                                                VEGA Tools App, PACTware/DTM, IODD
   CY
              point level and pressure is the best guarantee   of process automation, VEGA has built up extensive                                                                                 Three-wire: IO-Link, PNP/NPN, 4 ... 20 mA (active)
   CMY
              for ecient and reliable automation.             know-how for solving the most demanding of measurement                                                                             Wireless setup with Bluetooth
   K                                                                                                                                                 360° status display
              Take advantage of VEGA’s expertise in the        tasks. Now, by transferring this knowledge to factory                                                                              M12 plug connection
              implementation of innovative measurement         automation, it oers customers a comprehensive range                                                                                 Protection class IP66/67/69
              technology solutions.                            of compact level and pressure sensors with IO-Link.                                   On-site display with
                                                                                                                                                       VDMA operation                               Measuring range up to 15 m
                                                                                                                                                       and super-bright                           Measurement accuracy ± 2 mm
                                                                                                                                                     360° status display
                                                               The complete IO-Link instrument family                                                                                             Temperature range
                                                               In addition to point level and pressure, VEGA is now                                                                                 -40 °C ... +130 °C/15 min @ +150 °C steam
              Compact sensors                                    rounding out the IO-Link portfolio for factory automation                             All-metal housing                            Pressure range -1 ... +16 bar
              from a single source                             with a radar level measurement sensor.                                                                                             Standard thread ¾", 1" or universal connection
                                                                  This now means a range of sensors with IO-Link                                                                                  for hygienic adapter G1"

                 Accessories and fittings compatible               communication are available for level, point level and
                with the entire IO-Link instrument series         pressure in the field of factory automation
                 Reduced stock-holding holding                     This compact IO-Link family is fully equipped with                        With VEGAPULS 42, the advantages of radar          IO-Link with
                 Extremely simple setup,                            versatile hygienic adapters                                              measurement technology are available to a greater  Smart Sensor Profile 2
                                                                                                                                             variety of processes and industries, enabling even
                thanks to universal presets                                                                                                  more potential for factory automation. Here, radar    Configuration and parameters according
                                                               New addition:
                Reliable monitoring of level,                  The VEGAPULS 42 continuous radar level sensor                                 oers the best choice for continuous, non-contact    to the standardised IODD system
                point level and pressure                                                                                                     level measurement or point level switching.           Adjustment data from other sensors
                                                                   Designed and optimised for vessels                                        Because, unlike ultrasonic sensors for example,
                Easy visualisation enabled                        up to 15 metres high                                                                                                            transferred 1:1, regardless of the
                by 360° status display                             Capable of handling very fast level changes                               radar technology is not aected by the process       measuring principle
                                                                                                                                             conditions and operating environment.
                                                                   Experience from over 30 years of technology leadership
                                                                  in radar level measurement
                                                                   The best radar chip available on the market, featuring
                                                                  the largest dynamic range and maximum bandwidth                            VEGA Instruments Co., Ltd.
                                                                  available                                                                  Tel.: +66 2700 9240       E-mail: info.th@vega.com        www.vega.com
   3   4   5   6   7   8   9   10   11   12   13